PWC3548: Unable to process print job due to timeout - c06406191
Using the steps below the administrator for the PrinterOn Enterprise solution is able to identify and resolve the problems that generate the error message: PWC3548: Unable to process print job due to timeout
Summary
- Verify what the Server Address value is on the printer giving the error
- Modify Printer Configuration to point to correct PDH Server Address
- Verify PDH address is defined correctly and service is started
Event Definition
If the Printer has not been updated to deliver jobs to the PDH address, it will attempt to deliver jobs to 127.0.0.1:631, but there is nothing available or listening on that port. This error will also be shown when the PDH address has been defined incorrectly (check for typos!), or the PDH service is unavailable (check if the PDH service is started & load balancer is in active state). The result is a PWC3548: Unable to process print job due to timeout. error.
Procedure Documentation
Symptoms and Errors
- Long processing time (10+ minutes due to PrintWhere timeout)
- "PWC3548: Unable to process print job due to timeout." error shown eventually
- Job does not complete processing
Tools and Access Needed
- Client Name
- AWS Administrator access
- Administrator Permissions to PONCONF
- PONCONF access
Post Resolution Expected Behaviour
Jobs should be processed and a "Complete" message displayed to end users.
Pre Event Reporting/Documentation
If this is occurring after initial deployment stage, or the customer reported the issue, create a case in Salesforce
Event Start Notification Procedure
n/a
Steps and Process
There are multiple possible resolutions to this error
Verify PDH configuration on printer definition:
- Log in to PONCONF
- View Printer Configuration for the printer giving the error
- Expand Output Location section
-
Review the PDH Server Address field
It should reflect the customer's PDH: https://pdh-client.printanywhere.com:443 - If this value is incorrect (check for typos too!), update and save changes
- If this value was already configured correctly, move on to the next set of steps to identify the cause
Verify PDH Services are started:
- Log in to PONCONF
- View the Services tab
- Verify PDH1 and PDH2 are started
- If both services are already started, move on to the next set of steps to identify the cause
Verify PDH LB is in a healthy state:
- Log in to AWS ( manservices )
- Go to OpsWorks area
- Click on your Client stack
- View the Instances
- Click on the PDH ELB
- Review the attached servers for their status
Event Complete Notification Procedure
n/a
Post Event Reporting/Documentation
Close Salesforce case if required
NOTE: